AI readiness is not a purchasing decision

An algorithm is only the visible end of a long chain. Before a model can contribute anything useful, a laboratory needs reliable digital slide infrastructure, sufficient computing and storage for large whole slide images, and interfaces that connect results back to the laboratory information system and the existing reporting workflow.

It also needs the parts that are harder to buy: local validation against representative cases, governance that defines intended use and accountability, quality processes that detect degradation over time, and a workforce with the capability and confidence to use the output appropriately. Weakness in any one of these areas limits the value of strength in the others.

Five readiness domains

  • 01

    Digital slide infrastructure

    Whole slide scanners, barcoding and image management systems determine whether cases can reach an algorithm at all. Scanner throughput, image quality control and slide preparation consistency set the ceiling for everything built above them.

  • 02

    Computing, network and storage

    Whole slide images can place substantial demands on storage and transfer. Sustainable adoption requires processing capacity, bandwidth, storage, retention, backup and recovery arrangements suited to the intended AI application and workload. GPU resources or a governed cloud pathway may be needed, depending on the application.

  • 03

    LIS and system integration

    An AI result that lives outside the laboratory information system creates parallel work rather than removing it. Interoperability through standards-based interfaces, worklists and structured reporting keeps outputs inside the pathologist's existing workflow.

  • 04

    Governance, validation and quality

    Local validation, defined intended use, performance monitoring and incident handling support responsible implementation. Establish clear accountability, documentation and review of changes and performance. Determine validation and revalidation needs according to the intended use, local risks and applicable institutional, accreditation and regulatory requirements.

  • 05

    Workforce capability and change management

    Pathologists, scientists and technologists need training in what a model does, where it fails, and how to escalate. Engagement, protected time and transparent communication determine whether a validated tool is actually used well.

Readiness assessment

Rate each domain from 1 (not established) to 5 (mature). Your profile updates automatically. Your assessment selections and score are calculated locally within your browser and are not submitted to or saved by this tool. Do not enter patient information or other confidential data. The website’s hosting provider may process routine technical information in accordance with its applicable privacy practices.

Who should use this tool? Pathologists, laboratory directors, laboratory scientists, quality managers, digital-pathology leads, healthcare IT personnel and multidisciplinary implementation teams.

Completion time: Completion time varies with the intended application, available evidence and use of the optional worksheet. Allow additional time for team discussion.

Choose one intended AI application before rating. Where a domain includes several elements, rate its weakest relevant element. Team members can complete the assessment independently, then compare their domain profiles.

The level descriptions in “What do these levels mean?” are illustrative anchors to support discussion. They have not been validated as measurement thresholds.

  1. 1.How mature is the laboratory's digital slide infrastructure?
    What do these levels mean?
    1 Not established —
    No routine whole-slide imaging capability or defined implementation plan.
    2 Early —
    Limited scanner access or pilot use; manual identification; quality control and downtime arrangements largely informal.
    3 Partial —
    Some routine scanning and barcoding; variable coverage, capacity monitoring or documented image-quality control.
    4 Substantial —
    Validated routine workflows with documented identification, image-quality control, capacity planning and downtime procedures.
    5 Mature —
    Integrated, monitored and scalable digital-slide service with consistent pre-analytics, quality metrics, resilience and continuous improvement.
  2. 2.How adequate are its computing, network and storage resources?
    What do these levels mean?
    1 Not established —
    No assessed capacity for the intended AI workload.
    2 Early —
    Ad hoc or pilot resources without documented capacity, retention, backup or resilience planning.
    3 Partial —
    Core compute, network and storage exist, but capacity, performance, backup or growth planning is incomplete.
    4 Substantial —
    Resources are documented, monitored and adequate for validated routine use, with backup and recovery arrangements.
    5 Mature —
    Scalable, resilient and costed infrastructure with lifecycle capacity management, security controls and governed on-premise or cloud pathways.
  3. 3.How well can new tools integrate with the LIS and existing workflow?
    What do these levels mean?
    1 Not established —
    AI output would remain separate from case identification, worklists and reporting.
    2 Early —
    Manual transfer or isolated pilot integration with substantial duplicate work.
    3 Partial —
    Some interfaces or structured outputs exist, but workflow coverage, identity matching or access governance is incomplete.
    4 Substantial —
    Validated integration supports routine worklists, case identity, reporting and appropriate access controls.
    5 Mature —
    Standards-based, monitored and resilient integration supports traceability, privacy, cybersecurity, downtime recovery and workflow optimisation.
  4. 4.How developed are its validation, governance and quality processes?
    What do these levels mean?
    1 Not established —
    No documented intended use, local validation, accountable owner or approval pathway.
    2 Early —
    Governance discussions or draft plans exist, but validation, oversight and monitoring are incomplete.
    3 Partial —
    Intended use and responsibilities are defined; some representative local validation and documentation exist, with gaps in monitoring, fairness, incident handling or vendor assurance.
    4 Substantial —
    Documented governance covers intended use, representative validation, human oversight, limitations, regulatory review, monitoring and incident response.
    5 Mature —
    Lifecycle governance includes accountable ownership, subgroup/fairness review, change control, vendor oversight, drift monitoring, incident learning and periodic revalidation.
  5. 5.How prepared and engaged is its workforce?
    What do these levels mean?
    1 Not established —
    Roles, training and human oversight have not been defined.
    2 Early —
    Awareness exists, but training, protected time, escalation and engagement are informal.
    3 Partial —
    Key staff have initial training and defined roles, but coverage, confidence, escalation or competency assessment is incomplete.
    4 Substantial —
    Multidisciplinary roles, training, competency, escalation and change-management processes support routine use; the pathologist retains final authority.
    5 Mature —
    Ongoing competency, feedback, human-factors monitoring, transparent communication and continuous workforce improvement are embedded.

0 of 5 domains rated

Reset all clears your ratings and any worksheet entries.

Please rate all five domains to see your domain profile.

Please note: this is an educational discussion tool intended to prompt discussion and planning. It is not a formal accreditation, certification or regulatory assessment, and it does not substitute for institutional review or the requirements of your accrediting body. This author-developed, literature-informed framework has not been validated as an instrument.

About this assessment

This author-developed, literature-informed educational discussion framework is intended to support structured conversation and implementation planning. It has not been developed or validated as a psychometric instrument, accreditation standard or regulatory assessment. Organisations should interpret the result alongside their local clinical context, intended use, governance requirements and applicable accreditation and regulatory obligations.

Method and evidence

  • Version 2.0 — Educational prototype
  • Revision date: 22 November 2026.
  • Author-developed and literature-informed.
  • Intended audience: pathologists, laboratory directors, laboratory scientists, quality managers, digital-pathology leads, healthcare IT personnel and multidisciplinary implementation teams.
  • The five domains provide a concise sociotechnical overview.
  • Response anchors are illustrative and unvalidated.
  • No benchmarking, accreditation, certification, psychometric or regulatory claim is made.
  • Interpretation must consider intended use, local jurisdiction, infrastructure and resource setting.

Ratings are self-reported, using illustrative ordinal levels. The numbers do not establish equal differences in capability. The descriptive total is the unweighted sum of the five ratings (5–25); it has no validated cut-off and should not be used to rank institutions or authorise deployment. Stronger ratings do not compensate for gaps in other domains.

A rating of 1 or 2 triggers an author-defined educational advisory. This is not a validated threshold for clinical risk or implementation suitability, and the absence of an advisory does not establish readiness to deploy.

The selected references inform the topics covered by the toolkit. The five-domain structure, response anchors and advisory rules are author-developed; citing these sources does not establish endorsement or validation of the toolkit. Where an anchor refers to a validated workflow or application, that wording does not mean that this assessment instrument has been validated.

References

  1. World Health Organization. Ethics and governance of artificial intelligence for health. 2021.
  2. Lekadir K, et al. FUTURE-AI: international consensus guideline for trustworthy and deployable artificial intelligence in healthcare. BMJ. 2025;388:e081554.
  3. International Medical Device Regulators Forum. Good machine learning practice for medical device development: Guiding principles. IMDRF/AIML WG/N88 FINAL:2025.
  4. Evans AJ, et al. Validating Whole Slide Imaging Systems for Diagnostic Purposes in Pathology. Arch Pathol Lab Med. 2022;146(4):440–450. doi:10.5858/arpa.2020-0723-CP.
  5. ISO/IEC 42001:2023. Information technology — Artificial intelligence — Management system.
  6. NIST. Artificial Intelligence Risk Management Framework (AI RMF 1.0). NIST AI 100-1. 2023.

Readiness should be interpreted in the context of the intended clinical use, applicable national requirements, institutional governance, available infrastructure and local resources. A lower score may represent an appropriate starting point for phased development rather than failure.

About the author

Professor Pathmanathan Rajadurai

Professor Pathmanathan Rajadurai, MBBS, MPath, MD (Distinction), is Senior Consultant Anatomical and Molecular Pathologist and Laboratory Director at Subang Jaya Medical Centre, and Honorary Professor of Pathology at the University of Malaya.

His professional and academic interests include molecular diagnostics, digital pathology, telemedicine and the responsible implementation of artificial intelligence in laboratory medicine. His work emphasises clinically meaningful adoption, local validation, quality assurance, governance, workflow integration and workforce readiness.